SAGE Journals Online
Advertisement
Sign In to gain access to subscriptions and/or personal tools.

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Advertisement

Sign In to gain access to subscriptions and/or personal tools.
Angiology
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Urayama, H.
Right arrow Articles by Kawasaki, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Urayama, H.
Right arrow Articles by Kawasaki, S.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Increasing Circulation in the Lower Limb Under General Anesthesia Using the A-V Impulse System

Hiroaki Urayama, MD

Department of Surgery, Shinshu University School of Medicine, Matsumoto, Japan.

Kenichi Tanaka, MD

Department of Surgery, Shinshu University School of Medicine, Matsumoto, Japan.

Daisuke Fukui, MD

Department of Surgery, Shinshu University School of Medicine, Matsumoto, Japan.

Seiji Kawasaki, MD

Department of Surgery, Shinshu University School of Medicine, Matsumoto, Japan.

The action of foot impulse technology (FIT) in reducing the risk of deep vein thrombosis (DVT) is well established. We hypothesized that intraoperative use of FIT devices will be effective in the prophylaxis of DVT. The aim of this study was to investigate the effect of a FIT device (A-V impulse system) on the venous flow of the lower extremity using duplex ultrasound scanning while the patient was under general anesthesia. Thirteen surgical patients who had no lower limb vessel lesions were selected for the study. Duplex scanning was used to measure blood velocity in the right common femoral vein, with and without the foot pump, before and during general anesthesia. The mean resting velocity was 33.2 ±5.5 cm/sec in the pre-anesthetic state, 32.1 ±4.2 cm/sec under anesthetic, and 30.4 ±5.0 cm/sec postoperatively. The peak velocities with the pump active were 38.6 ±5.0 cm/sec before anesthetic, 54.6 ±5.9 cm/sec while anesthetized, and 52.7 ±7.8 cm/sec postoperatively. The measured increases while under anesthesia and postoperatively both reached statistical significance (p < 0.05). Our study demonstrated that use of the A-V impulse system causes a statistically significant increase in venous velocity of the lower extremity while the patient is under general anesthesia.

Angiology, Vol. 54, No. 6, 691-694 (2003)
DOI: 10.1177/000331970305400608


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?




Advertisement