SAGE Journals Online
Advertisement
Sign In to gain access to subscriptions and/or personal tools.

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Advertisement

Sign In to gain access to subscriptions and/or personal tools.
Angiology
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Mauser, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mauser, M.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Acute Success Rates of Percutaneous Transluminal Coronary Angioplasty in the Treatment of Chronic Complete Occlusions with Use of the 0.014 Magnum Meier Wire

Manfred Mauser, MD, FACA

Klinikum Lahr Med. Klinik, Abt. Kardiologie 77933 Lahr Germany

The 0.014 inch magnum Meier wire was used as the primary tool for recanalization of chronic total coronary artery occlusions in 230 consecutive patients treated by a single operator over a 3-year period. Exclusive use of the magnum wire resulted in an acute success rate of 80.9% in all occlusions and 64.7% in occlusions with a duration of > 6 months. The complication rate of this procedure was extremely low with only one nontransmural myocardial infarction occurring. There were no vessel perforations, no in-hospital deaths, and no need for acute surgery. After failure to recanalize with the magnum wire, various other devices (conventional stiff guidewires, jagwire, crosswire) were used resulting in only six additional successful recanalizations but also in two vessel perforations with spontaneous closure of the perforation hole. Therefore, the 0.014-inch magnum Meier recanalization wire is highly effective for recanalization of chronic coronary artery occlusions, if used as the primary tool by an experienced operator, and is associated with an extremly low complication rate.

Angiology, Vol. 51, No. 10, 849-854 (2000)
DOI: 10.1177/000331970005101007


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?




Advertisement