Angiology

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Click here for more information

Sign In to gain access to subscriptions and/or personal tools.
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Scavetta, K.
Right arrow Articles by Ribeiro, P. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Scavetta, K.
Right arrow Articles by Ribeiro, P. A.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Angiology, Vol. 50, No. 11, 891-899 (1999)
DOI: 10.1177/000331979905001103

Results of Saphenous Vein Graft Stent Implantation: Single Center Results from Use of Oversized Balloon Catheters

Karen Scavetta

Christopher Oh

Randall Caldron

Tarek Abdel-Dayem

Muayed Al-Zaibag

Kenneth R. Jutzy

Robert J. Marsa

Matts Sjolander

Paulo A. Ribeiro

The results and complications of a single-center experience of stent implantation in old saphenous vein grafts (SVGs) need to be defined. The authors studied their initial consec utive 92 patients (125 stents, 1.4 stents/per patient) with a mean age of 67 ±9 years. The patients' mean saphenous vein graft (SVG) age was 10 ±4 years, and the mean left ventricular ejection fraction was 46% ± 15. Patient population included unstable angina (65%), stable angina (10%), myocardial infarction (21%), and silent ischemia (4%). The authors implanted 122 Palmaz-Schatz/biliary and three Gianturco-Roubin stents. They aimed at a balloon-artery ratio of 1.1/1.0. Procedural success, defined as stent deployment with <50% stenosis without death/Q-wave myocardial infarction/coronary artery bypass grafting (MI/CABG) was 95%. The mean luminal diameter (MLD) increased from 0.6 ±0.5 to 3.3 ±0.8 mm (p<0.001) and mean SVG stenosis diameter was decreased from 80% ± 14 to -10% ±11 (p<0.001). Angiographic SVG lesions exhibited thrombus (17%), ulceration (38%), and plaque rupture (28%). Sixty-two patients were treated with warfarin and aspirin and 30 with ticlid and aspirin. Complications included death in three patients (3.3%) who sustained subacute stent thrombosis, and two of three had Q- wave MI. Distal embolization occurred in seven patients (8%); six of seven sustained a non Q-wave acute myocardial infarction (AMI); and one of seven a Q-wave MI. Eight (9%) patients had major groin hematoma, two had pseudoaneurysm (2.2%), one had arteriovenous (A-V) fistula (1.1%), two had vascular surgery (2.2%), nine had blood transfusion (9.8%), and three had stent migration (3.3%). Single-center experience with stents in SVGs indicates a highly successful procedural and angiographic immediate result. However, it was complicated by significant risk of non Q-wave MI due to distal coronary embolization which may affect prognosis.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?