SAGE Journals Online
Advertisement
Sign In to gain access to subscriptions and/or personal tools.

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Advertisement

Sign In to gain access to subscriptions and/or personal tools.
Angiology
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Gardner, A. W.
Right arrow Articles by Gardner, A. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gardner, A. W.
Right arrow Articles by Gardner, A. W.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Reliability of Transcutaneous Oximeter Electrode Heating Power During Exercise in Patients with Intermittent Claudication

Andrew W. Gardner, PhD, FACA

Andrew W. Gardner, PhD, FACA

Baltimore Veterans Affairs Medical Center Geriatrics/GRECC (18) 10 North Greene Street Baltimore, MD 21201-1524

The purposes of this study were to (1) compare the reliability of transcutaneous oximeter electrode power with the reliability of oxygen tension and (2) compare the relationship of the oximetry measures with exercise performance in claudicants. One hundred ten PAOD patients with stable claudication symptoms performed a treadmill test and had the following exercise measures obtained: foot transcutaneous oxygen tension, oximeter electrode heating power, exercise duration, and peak oxygen consumption. A subset of 30 patients were tested once per week over three successive weeks to assess the reliability of the oximetry measures. The coefficient of variation of foot transcutaneous oxygen tension at peak exercise was 32.8%, whereas the variability of the oximeter electrode heating power was only 5.1%. Oximeter electrode heating power at peak exercise was related to maximal claudication pain time (r=0.44, P < 0.001) and peak oxygen consumption (r=0.36, P < 0.001), whereas foot transcutaneous oxygen tension was not related to either (r=0.15, P=0.119; r=0.13, P=0.189; respectively). Thus, transcuta neous oximeter electrode heating power was six to seven times less variable than tran scutaneous oxygen tension, and the oximeter electrode power at peak exercise was more closely related to exercise capacity. It is concluded that the measurement of transcuta neous oximeter electrode heating power during exercise is more reliable and better corre lated with exercise capacity in PAOD patients with intermittent claudication than the measurement of transcutaneous oxygen tension.

Angiology, Vol. 48, No. 3, 229-235 (1997)
DOI: 10.1177/000331979704800305


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?


This article has been cited by other articles:


Home page
ANGIOLOGYHome page
A. Afaq, P. S. Montgomery, K. J. Scott, S. M. Blevins, T. L. Whitsett, and A. W. Gardner
The Effect of Hypercholestrolemia on Calf Muscle Hemoglobin Oxygen Saturation in Patients With Intermittent Claudication
Angiology, October 1, 2008; 59(5): 534 - 541.
[Abstract] [PDF]



Advertisement