SAGE Journals Online
Advertisement
Sign In to gain access to subscriptions and/or personal tools.

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Advertisement

Sign In to gain access to subscriptions and/or personal tools.
Angiology
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Bude, R. O.
Right arrow Articles by Adler, R. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bude, R. O.
Right arrow Articles by Adler, R. S.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

The Effect of Poststenotic Vessel Wall Compliance upon the Pulsus Tardus Phenomenon

Ronald O. Bude

Department of Radiology, University of Michigan Medical School, Ann Arbor, Michigan

Jonathan M. Rubin

Department of Radiology, University of Michigan Medical School, Ann Arbor, Michigan

Joel F. Platt

Department of Radiology, University of Michigan Medical School, Ann Arbor, Michigan

Ronald S. Adler

Department of Radiology, University of Michigan Medical School, Ann Arbor, Michigan

Recent studies have investigated the detection of significant arterial stenoses through identification of the "pulsus tardus" phenomenon in Doppler waveforms obtained distal to the stenosis. The etiology of this phenomenon, however, has not yet been determined. Using an in vitro model based upon an electrical circuit analogy, the authors had as their objective to determine whether the compliance of the vessel wall immediately distal to a stenosis, in conjunction with the stenosis, is the cause of pulsus tardus. For a constant stenosis, it was found that the degree of pulsus tardus, as quantitated by the acceleration index, increased as the compliance of the poststenotic segment increased. It is concluded that pulsus tardus distal to an arterial stenosis is likely due to the compliance of the normally distensible artery, in conjunction with the stenosis. Pathological conditions that alter the compliance of the poststenotic segment may affect the degree of pulsus tardus, perhaps limiting its usefulness for upstream stenosis detection.

Angiology, Vol. 45, No. 7, 605-611 (1994)
DOI: 10.1177/000331979404500703


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?




Advertisement