SAGE Journals Online
Advertisement
Sign In to gain access to subscriptions and/or personal tools.

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Advertisement

Sign In to gain access to subscriptions and/or personal tools.
Angiology
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Dill, H.
Right arrow Articles by Bachmann, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Dill, H.
Right arrow Articles by Bachmann, K.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Doppler Flow Velocity Measurements During Coronary Angioplasty

Harald Dill

Medizinische Klinik mit Poliklinik, University Erlangen-Nuremberg, Germany

Robert Altstidl

Medizinische Klinik mit Poliklinik, University Erlangen-Nuremberg, Germany

Matthias Regenfus

Medizinische Klinik mit Poliklinik, University Erlangen-Nuremberg, Germany

Hans Lehmkuhl

Medizinische Klinik mit Poliklinik, University Erlangen-Nuremberg, Germany

Kurt Bachmann

Medizinische Klinik mit Poliklinik, University Erlangen-Nuremberg, Germany

In addition to further studies using Doppler catheters to assess blood flow velocity during coronary angioplasty this study intends to evaluate the functional significance of coronary stenoses and to estimate their hemodynamic relevance prior to and after percutaneous transluminal coronary angioplasty (PTCA). Diameters of coronary artery stenoses were quantified by means of the cardiovascular angiographic analysis system (CAAS) both prior to and following successful PTCA in 37 patients. During coronary artery angioplasty a 12 M:Hz 0.018-in. Doppler-tipped guidewire was used to measure prestenotic and post stenotic parameters of coronary artery flow velocity both prior to and following PTCA. The minimal stenosis diameter was raised from 1.01 ±0.58 to 1.76 ±0.73 mm (P < 0.0001), the percent diameter stenosis decreased from 63 ±11 to 35 ±6% (P < 0.0001). Prestenotic average (APV) and maximum peak velocity (MPV), peak velocity integral (PVI), average systolic (ASPV) and diastolic (ADPV) peak velocity, systolic (SPVI) and diastolic (DPVI) peak velocity integral, and diastolic/systolic velocity ratio showed—in contrast to further studies—a considerably significant difference (P < 0.05), whereas poststenotic Doppler data (APV, MPV, PVI, ASPV, DSPV, SPVI, DPVI, DSVR) differed highly significantly (P < 0.0001) prior to and following PTCA. Prestenotic and poststenotic measurements of coronary artery flow velocity differed significantly before and after PTCA and offer the potential for estimating both the hemodynamic relevance of coronary artery stenoses and success of PTCA.

Angiology, Vol. 45, No. 10, 877-882 (1994)