SAGE Journals Online
Advertisement
Sign In to gain access to subscriptions and/or personal tools.

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Advertisement

Sign In to gain access to subscriptions and/or personal tools.
Angiology
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Fleming, R. M.
Right arrow Articles by Swafford, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fleming, R. M.
Right arrow Articles by Swafford, J.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Quantitative Coronary Arteriography and Its Assessment of Atherosclerosis

Part I. Examining the Independent Variables

Richard M. Fleming

Center for Clinical Cardiology and Research

Gordon M. Harrington

The University of Northern Iowa

Harry R. Gibbs

University of Texas M. D. Anderson Cancer Center

Joseph Swafford

University of Texas M. D. Anderson Cancer Center

Background. Previous work has demonstrated that quantitative coronary arteriography (QCA) can accurately measure phantom images to within ±0.1 mm and has been accepted as a reliable and reproducible method of measuring human coronary artery disease (CAD). Assessment of CAD by QCA involves the measurement of numerous variables, which are currently required to calculate stenosis flow reserve (SFR).

Methods and Results. In this study 1040 stenotic lesions were analyzed by two well- accepted methods with demonstrated accuracy and reproducibility. These methods measure percent diameter stenosis (%DS), absolute diameter, percent area stenosis, length, as well as entry and exit angles to and from a stenotic coronary artery lesion respectively Based upon these results, the mean ± standard deviations and range seen in CAD were determined for each of these independent variables. This study demonstrated that atherosclerotic coronary artery lesions do not appear to exceed an entry angle of -39°, an exit angle of +35°, or an absolute length of 4.84 cm when accurately measured by QCA. It was also noted that, once percent diameter stenosis exceeded 89% (regardless (continued on next page) of the visual estimate) or percent area stenosis exceeds 99%, coronary arteries become completely occluded as measured by QCA.

Conclusions. While previously suspected that once certain critical limits are exceeded in the deposit of cholesterol and calcium within the coronary artery, the artery will close, this study demonstrated by QCA what the limitations in human coronary arteries appear to be. These limits may be in part due to turbulent factors resulting in platelet activation or local mediators from endothelium of the coronary artery.

ABSTRACT

Contemporary quantitative coronary arteriography (QCA) was used to measure the different variables present in atherosclerotic coronary arteries. While the interaction of each of the independent variables undoubtedly plays a role in the determination of coronary artery blood flow and closure, the limitations of each of these variables have not yet been defined in humans. This study, based on the results of human coronary arteri ograms as analyzed by QCA, demonstrates the limitations of each of these variables, after which coronary arteries close and blood flow equals zero.

Angiology, Vol. 45, No. 10, 829-833 (1994)
DOI: 10.1177/000331979404501001


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?




Advertisement