SAGE Journals Online
Advertisement
Sign In to gain access to subscriptions and/or personal tools.

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Advertisement

Sign In to gain access to subscriptions and/or personal tools.
Angiology
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Höflin, F.
Right arrow Articles by Rösler, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Höflin, F.
Right arrow Articles by Rösler, H.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Routine 18F-2-Deoxy-2-Fluoro-D-Glucose (18F-FDG) Myocardial Tomography Using a Normal Large Field of View Gamma-Camera

F. Höflin

H. Ledermann

U. Noelpp

R. Weinreich

H. Rösler

There is a recent need to study glucose metabolism of the heart in is chemic, as well as in "hibernating or stunned" myocardium, and compare it with that in perfusion studies. In non-positron emission tomography centers, positron imaging is possible with a standard Anger-type camera if proper collimation and adequate shielding of the camera crystal can be achieved. For the study with fast-de caying isotopes, seven-pinhole tomo graphy (7PHT), a limited-angle method designed for transaxial tomo graphy of the left ventricle using a nonrotating camera, is well suited, because projections are acquired si multaneously. Individual adjustment (patient supine) of the camera's view axis (CAx) with the left ventricular axis (LVAx) gives excellent results: sensitivity for CHD 82%, specificity 72% in a prospective 201TI study (48 patients, x-ray coronarography as reference). Good alignment of CAx with LVAx is also achieved with the patient prone in LAO in a hammock above the camera surface. In this set ting additional lead shielding of the camera is possible using a table rein forced with 5 cm of lead with a cen tral hole for the 7PH-collimator, which has a special lead inlay. This allows utilization of the 511 KeV emitter 18F-FDG, which with a half- life of 109 minutes, can be trans ported a reasonable distance from the production site. System sensitiv ity and resolution for 18F was found comparable to 201Tl, 99mTc, and 123 I us ing a phantom. First clinical exami nations after 201Tl stress/redistribu tion studies showed increased 18F- FDG uptake in ischemic heart segments, as well as in "hibernating" nonperfused or "stunned" myocar dium.

Angiology, Vol. 40, No. 12, 1058-1064 (1989)
DOI: 10.1177/000331978904001207


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?




Advertisement