SAGE Journals Online
Advertisement
Sign In to gain access to subscriptions and/or personal tools.

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Advertisement

Sign In to gain access to subscriptions and/or personal tools.
Angiology
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Prickett, C.
Right arrow Articles by Johnson, J. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Prickett, C.
Right arrow Articles by Johnson, J. L.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Assessing Opacification and Flow Rates of Contrast Media in Neonate and Pediatric Cardiac Catheterization

Charles Prickett

University of Southern California Medical School, Los Angeles, California

John Leslie Johnson

University of Southern California Medical School, Los Angeles, California

The accuracy and advantages of determining the flow rates of opaque media in catheters used in the infant and pediatric age group is essential in obtaining proper opacification with minimum toxicity to the patient. Flow rates expressed as cubic centimeters per second and grams of iodine per second were determined by using representative standard pediatric catheters in various sizes and lengths. Three representative opaque medias were used to determine these findings. Although present-day injector pumps are frequently calibrated in delivery rates, they cannot be applied directly to the cardiac catheters usually used with infants and small children.

Angiology, Vol. 29, No. 11, 817-824 (1978)
DOI: 10.1177/000331977802901105


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?




Advertisement